Monessen
About this model
The Monessen Lo-Rider 36 is a single-sided vent-free firebox enclosure for a separately selected gas log heater and burner. Its low hearth and tall opening create a traditional fireplace appearance. Concealed screen pockets and circulating air channels complement the design.
Choose concrete or multitonal brick-style interior configurations, with reflective glass available as an upgrade. Model-listed finishing and accessory choices are shown below.
Firebox only: logs, burner, controls, gas supply and installation are separately selected and quoted. Photographs show complete installations and may include optional equipment and room finishes. Washburn’s will confirm the heater's fit, fuel and installation requirements.
Specifications
- Product classification
- Standalone vent-free firebox enclosure; gas logs, burner and controls sold separately
- Manufacturer model family
- LCUF36CR-C / -GT / -GH / -BT
- Fuel
- Natural gas or propane determined by separately selected compatible gas log heater; no solid fuel
- Maximum approved heater input
- 40,000 BTU/hr; actual output/input depends on separate listed heater, fuel and altitude
- Unit width × height × depth
- 42 × 34 × 23 in — installation manual
- Viewing opening
- 36 × 30 in — installation manual
- Framing width × height × depth
- 42.5 × 34-1/4 × 22-3/4 in; adjust for trim and finish as instructed
- Hearth front width
- 32-7/8 in
- Hearth rear width
- 24-3/8 in — installation manual
- Hearth depth
- 15 in
- Hearth front / rear height
- 28-1/2 / 22-5/8 in
- Weight by liner configuration
- 175 lb CR-C; 110 lb GT, GH or BT
Standard features
Clean-face circulating firebox with an angled interior and air channels designed to move warmth from a separately installed log heater into the room. Curtain mesh screens retract into concealed side pockets.
Gas-line access points and a junction box support the separately planned gas and electrical connections.
Flush-hearth design with a taller opening. Select traditional concrete, gray stacked, gray herringbone or brown stacked liner configuration; the supplied liner follows that model suffix.
Required components
Select a compatible listed vent-free gas log heater, matching burner, fuel type and controls separately. The heater must fit the firebox's minimum internal dimensions and remain within its 40,000 BTU/hr limit. This enclosure alone does not produce heat.
A regulated gas supply, site-appropriate framing, finishing materials, combustion/ventilation air and professional installation are required. Logs and burner must follow their own installation instructions as well as the firebox manual.
Install the supplied hood or canopies as directed. Plan electrical supply before closing the wall when using lights, a fan or electrically powered controls. Installation, materials, gas work, finishing, delivery, accessories and tax are separate.
Optional features and accessories
Optional GFK-160VF fan and MONAL-VF accent light kit. The light kit operates on 120 VAC, 60 Hz and may illuminate the firebox with or without the gas flame.
Fronts and Doors: Doors - Operable; Front — Black. Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Lighting: Accent Light Kit. Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Mantel Shelves: Baxter 59" — Unfinished; Baxter 59" — Primed; Crosby 59" — Primed; Crosby 59" — Unfinished; Fillmore 59" — Primed; Fillmore 59" — Unfinished; Non-Combustible Cove Gray 60"; Non-Combustible Midnight Mist 60"; Non-Combustible Tavern Brown 60"; Non-Combustible Washed Cedar 60"; Non-Combustible Weathered Barnwood 60"; Non-Combustible White 60"; Ozark 59" — Primed; Ozark 59" — Distressed Knotty Alder; Ozark 59" — Unfinished. Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Mantels: Acadia B — Primed; Acadia B — Unfinished; Battlefield B — Primed; Battlefield B — Distressed Knotty Alder; Corbels; Kenwood B — Primed; Kenwood B — Unfinished; Kenwood B60 — Primed; Laurel B — Primed; Malone B — Primed; Merritt B — Primed; Roxborough B — Primed; Walker B — Primed; Wescott B — Primed; Zimmer B — Primed. Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Powered Fans: Fan. Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Additional installation accessories: AKD outside-air kit; LCUF36CR matching trim kit. Outside-air kit is optional unless required by the installation or local rules; ducting is separate.
Features & options
Features & options
Review available selections. Included equipment and any additional charges are confirmed on your quote.
Required gas log heater
(required)
Other selections
- Natural gas log and burner package
- Propane log and burner package
This product is a firebox enclosure only. A compatible listed vent-free gas log heater, burner, controls and gas supply are separately required.
Firebox interior configuration
(required)
Select the correct CR-C, CR-GT, CR-GH or CR-BT liner configuration; reflective glass is a separate upgrade.
Fronts and Doors
Other selections
Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Separately selected logs and burner
(required)
A listed compatible gas log heater and burner are required but are not included in this firebox. The choices shown are manufacturer-listed styles; installation fit, fuel and control must be confirmed. An enhancement kit alone does not complete the heater.
Lighting
Other selections
Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Mantel Shelves
Other selections
Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Mantels
Other selections
Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Powered Fans
Other selections
Model-listed options are separately selected. Mantel, shelf and surround choices still require site clearance review.
Additional installation accessories
Other selections
- No additional accessories
- AKD outside-air kit
- LCUF36CR matching trim kit
Outside-air kit is optional unless required by the installation or local rules; ducting is separate.
Technical notes
For approved vent-free gas log heaters only; never burn wood or other solid fuel. The system is supplemental heat or decorative use, not a primary heating system.
Location, room air supply, fuel choice and local permission for vent-free use must be checked by the installer. Maintain unobstructed combustion and ventilation openings and follow both the heater and firebox manuals.
Keep furniture and other flammable objects at least 36 in from the front. Mantel height depends on projection; follow the manual's diagrams. Carpet and vinyl have special hearth requirements and must not be assumed safe next to a flush opening.
Photos show complete installations with separate log heaters, burners, optional trim, liners and room finishes. Shared series photos may depict another size.
The website's 36-inch viewing width and the brochure's viewing height/framing height differ from the current manual. Specifications here follow the November 2025 LCUF manual; confirm the exact shipped unit before construction.